Products

E3F18-D30C Diffuse-reflective Photoelectric Sensor

Designed for non-contact detection by receiving light reflected directly from the object. An adjustable sensing distance supports installation for different object positions. The M18 housing and pre-wired connection facilitate equipment integration. An operation indicator supports commissioning and status monitoring. Suitable for object presence detection, counting and conveyor automation. Detection depends on the object surface and reflectivity.

Technical Parameters

Product Model E3F18-D30C
Output NPN NO E3F18-D30C-NO
NC E3F18-D30C-NC
PNP NO E3F18-D30C-PO
NC E3F18-D30C-PC
Housing Diameter M18
Sensing Method Diffuse-reflective
Output Type NPN/PNP
Sensing Distance 30 cm (adjustable)
Sensing Object 100 × 100 mm white drawing paper
Differential Travel 20% of sensing distance or less
Light Source (Wavelength) Gallium arsenide infrared light-emitting diode (850 nm)
Power Supply Voltage 12 to 24 V direct current; ripple: 10% maximum, peak-to-peak (10 to 30 V direct current)
Current Consumption ≤25mA
Control Output Load current: 100 mA maximum (residual voltage: 1 V maximum)
Response Time Operate or reset: 1.0 ms maximum each
Protection Circuits Surge protection, output short-circuit protection and reversed power supply polarity protection
Indicator Operation indicator (red)
Ambient Temperature Range Operating: -25 to +55 °C; Storage: -30 to +70 °C, with no icing
Ambient Illumination (Receiver Side) Sunlight: 10000 lux maximum; incandescent lamp: 3000 lux maximum
Ambient Humidity Range Operating: 45% to 85% relative humidity; Storage: 35% to 95% relative humidity, with no icing
Voltage Influence Sensing distance changes by no more than ±1% when the supply voltage varies within ±15% of the rated range
Insulation Resistance 50 MΩ minimum, measured with a 500 V direct current megohmmeter between live parts and the housing
Dielectric Strength 1000 V alternating current minimum at 50/60 Hz for 1 minute between live parts and the housing
Vibration Resistance (Destruction) 10 to 55 Hz; 1.5 mm double amplitude for 1 hour each in the X, Y and Z directions
Shock Resistance (Destruction) 500 m/s² double amplitude, 3 times each in the X, Y and Z directions
Degree Of Protection IP67
Connection Method Pre-wired (standard cable length: 2 m)
Housing Material Case: Acrylonitrile butadiene styrene

Dimension

Wiring Diagram

Contact us

*For faster technical evaluation, please provide your current model, product photo, datasheet or drawing whenever available.

Contact Us Right Now

*For faster technical evaluation, please provide your current model, product photo, datasheet or drawing whenever available.