E3FJ18-T10M Through-Beam Photoelectric Sensor
Designed for non-contact detection with a separate emitter and receiver. An object is detected when it interrupts the infrared optical path between the two units. The through-beam arrangement is suitable for object detection and counting across conveyor lines or equipment openings. The M18 nickel-plated brass housing, pre-wired connection and operation indicator support installation and commissioning.
Technical Parameters
| TECHNICAL PARAMETERS | ||||
| Product Model | E3FJ18-T10M | |||
| Output | NPN | NO | E3FJ18-T10M-NO | |
| NC | E3FJ18-T10M-NC | |||
| PNP | NO | E3FJ18-T10M-PO | ||
| NC | E3FJ18-T10M-PC | |||
| Housing Diameter | M18 | |||
| Sensing Method | Through-Beam | |||
| Output Type | NPN/PNP | |||
| Sensing Distance | 10m | |||
| Sensing Object | Opaque object: diameter of 12 mm or greater | |||
| Differential Travel | 20% of sensing distance or less | |||
| Light Source (Wavelength) | Gallium arsenide infrared light-emitting diode (850 nm) | |||
| Power Supply Voltage | 12 to 24 V direct current; ripple: 10% maximum, peak-to-peak (10 to 30 V direct current) | |||
| Current Consumption | ≤45mA | |||
| Control Output | Load current: 100 mA maximum (residual voltage: 1 V maximum) | |||
| Response Time | Operate or reset: 1.0 ms maximum each | |||
| Protection Circuits | Surge protection, output short-circuit protection and reversed power supply polarity protection | |||
| Indicator | Operation indicator (red) | |||
| Ambient Temperature Range | Operating: -25 to +55 °C; Storage: -30 to +70 °C, with no icing | |||
| Ambient Illumination (Receiver Side) | Sunlight: 10000 lux maximum; incandescent lamp: 3000 lux maximum | |||
| Ambient Humidity Range | Operating: 45% to 85% relative humidity; Storage: 35% to 95% relative humidity, with no icing | |||
| Voltage Influence | Sensing distance changes by no more than ±1% when the supply voltage varies within ±15% of the rated range | |||
| Insulation Resistance | 50 MΩ minimum, measured with a 500 V direct current megohmmeter between live parts and the housing | |||
| Dielectric Strength | 1000 V alternating current minimum at 50/60 Hz for 1 minute between live parts and the housing | |||
| Vibration Resistance (Destruction) | 10 to 55 Hz; 1.5 mm double amplitude for 1 hour each in the X, Y and Z directions | |||
| Shock Resistance (Destruction) | 500 m/s² double amplitude, 3 times each in the X, Y and Z directions | |||
| Degree Of Protection | IP67 | |||
| Connection Method | Pre-wired (standard cable length: 2 m) | |||
| Housing Material | Nickel-plated brass | |||
Dimension

Wiring Diagram