Products

E3FJ12-D30C Diffuse-Reflective Photoelectric Sensor

Designed for non-contact detection by receiving light reflected directly from the object. Adjustable sensing distance supports installation for different object positions. The M12 nickel-plated brass housing and pre-wired connection facilitate equipment integration. An operation indicator supports commissioning and status monitoring. Suitable for object presence detection, counting and conveyor automation. Detection depends on object surface conditions and reflectivity.

Technical Parameters

TECHNICAL PARAMETERS
Product Model E3FJ12-D30C
Output NPN NO E3FJ12-D30C-NO
NC E3FJ12-D30C-NC
PNP NO E3FJ12-D30C-PO
NC E3FJ12-D30C-PC
Housing Diameter M12
Sensing Method Diffuse-Reflective
Output Type NPN/PNP
Sensing Distance 10 cm (adjustable)
Sensing Object 100 × 100 mm white drawing paper
Differential Travel 20% of sensing distance or less
Light Source (Wavelength) Gallium arsenide infrared light-emitting diode (850 nm)
Power Supply Voltage 12 to 24 V direct current; ripple: 10% maximum, peak-to-peak (10 to 30 V direct current)
Current Consumption ≤25mA
Control Output Load current: 100 mA maximum (residual voltage: 1 V maximum)
Response Time Operate or reset: 1.0 ms maximum each
Protection Circuits Surge protection, output short-circuit protection and reversed power supply polarity protection
Indicator Operation indicator (red)
Ambient Temperature Range Operating: -25 to +55 °C; Storage: -30 to +70 °C, with no icing
Ambient Illumination (Receiver Side) Sunlight: 10000 lux maximum; incandescent lamp: 3000 lux maximum
Ambient Humidity Range Operating: 45% to 85% relative humidity; Storage: 35% to 95% relative humidity, with no icing
Voltage Influence Sensing distance changes by no more than ±1% when the supply voltage varies within ±15% of the rated range
Insulation Resistance 50 MΩ minimum, measured with a 500 V direct current megohmmeter between live parts and the housing
Dielectric Strength 1000 V alternating current minimum at 50/60 Hz for 1 minute between live parts and the housing
Vibration Resistance (Destruction) 10 to 55 Hz; 1.5 mm double amplitude for 1 hour each in the X, Y and Z directions
Shock Resistance (Destruction) 500 m/s² double amplitude, 3 times each in the X, Y and Z directions
Degree Of Protection IP67
Connection Method Pre-wired (standard cable length: 2 m)
Housing Material Nickel-plated brass